Apc Mge Galaxy 5500 User Manual

Jun 01, 2008  APC by Schneider Electric. MGE GALAXY 5000. Data Center Grade Three Phase Uninterruptible Power Supply. Parallel Module - Guide Specifications. 40-130 kVA UPS. This specification describes a three-phase, on-line, double conversion, solid state Uninterruptible Power System hereafter referred to as the UPS. User manual APC MGE Galaxy 5000. Free manual and PDF download. Aks your question to other APC MGE Galaxy 5000 users. We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. APC MGE Galaxy 5000 manual.

Oct 23, 2012  Home » Spaces » Data Center & Facility 3 Phase UPS » discussion » General » PFC Fault on MGE Galaxy 5000 100KVA PFC Fault on MGE Galaxy 5000 100KVA. APC by Schneider Electric shall have no responsibility for the accuracy, correctness or objectionable nature of any user-submitted content, and disclaims any and all liability arising from.


The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this guide are the sole property of Schneider Electric SA and its subsidiaries. They may not be used for any purpose without the owner’s permission, given in writing.

This guide and its content are protected, within the meaning of the French intellectual property code (Code de la propriété intellectuelle français, referred to hereafter as “the Code”), under the laws of copyright covering texts, drawings and models, as well as by trademark law. You agree not to reproduce, other than for your own personal, noncommercial use as defined in the Code, all or part of this guide on any medium whatsoever without Schneider Electric’s permission, given in writing. You also agree not to establish any hypertext links to this guide or its content.

Schneider Electric does not grant any right or license for the personal and noncommercial use of the guide or its content, except for a non-exclusive license to consult it on an “as is” basis, at your own risk. All other rights are reserved.

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication.

Download Links for O&M Manuals

Apc Smart Ups User Manual

5500

Full operation, maintenance and specification documents can be downloaded or accessed via the external download links of apc/Schneider Electric website given below:


Advertising

MGE

TM

Galaxy

TM

5000

Apc Mge Galaxy 5500 User Manual Pdf

20 - 120 kVA

Installation and user manual

Advertising
Table of contents
  • 1. Presentation
    • 1.1 MGE TM Galaxy TM 5000
    • 1.2 Inside the UPS cabinet, access to connections
  • 2. Installation
    • 2.3 Removing the cardboard protecting the batteries
    • 2.4 Required protective devices and cable sizes
    • 2.5 2.5 System earthing arrangements
      • TNS upstream and TNS downstream installation
      • Frequency converter (without Bypass AC input)
    • 2.6 Connection of power cables in a single UPS unit
    • 2.8 Connection of power cables for parallel UPS units
      • Equipotential bonding between parallel-connected units
      • Redundant parallel configuration (maximum two UPS units for Pn)
    • 2.12 Auxiliary interconnections between UPS units in parallel configurations
    • 2.14 Connection of the relay communications card
    • 2.15 Running the control/communications cables
    • 2.17 Assembly and connection of an empty battery cabinet
  • 3. Operation
    • 3.5 Operation of mimic-panel LEDs
    • 3.6 Operating modes
    • 3.7 Load on battery power
    • 3.8 UPS personalisation
  • 4. Maintenance
    • 4.3 UPS isolation
      • UPS operating in ECO mode
      • Parallel UPS configuration without external bypass cabinet
      • Parallel UPS configuration with external bypass cabinet
    • 4.4 Return to the normal position
      • Parallel UPS configuration without external bypass cabinet
  • 5. Environment
  • 6. Available options
  • 7. Appendices
    • 7.1 Technical sheets
      • Center of gravity
      • Electrical characteristics
    • 7.2 Options